New Construction 2 Hours Fire Rated LED Housing HL-88273

This product is UL fire rated and can be protected for 2 hours with a double wall fixture incorporates a non-combustible fiber insulation to prevent flames, toxic gases, and ignition gases from passing through. Suitable for Condominiums, Apartment Buildings, Multi-Family, Commercial and Residential applications. Luminaire provides up to 2 hours of protection in L500, L505, L511, L536,L538, L541, L556, L577, M500, M510, M521 and M543 Floor-Ceiling Designs.

SKU: HL-88273 Category:

Description

DESCRIPTION

  • 2 Hours Fire Rated UL Listed (UL 1598 / UL 263)
  • Air Tight (ASTM Standard E283-04)
  • Pre-installed 3port push in quick connector
  • 13-5/8” to 25” Swivel Hanger Bar with pre-installed nails
  • Housing adjusts from 1-1/2” to accommodate various ceiling thickness
  • Ideal male orange quick connector (30-682M)
  • For use only with UL or cUL Classified LED Retrofit kit suitable for 4 inches recessed housing
  • Spacing of luminaires not to exceed one per 25 sq ft of ceiling area with min separation of 3 ft between luminaires

PLASTER FRAME

  • Galvanized steel plaster frame with integral bar hanger receivers.
  • The housing can be removed from plaster frame to provide access to the J-box.

HOUSING

  • Die formed galvanized steel housing with noncombustible fiber insulation.
  • Housing provides up to 2 hours of protection in L500, L505, L511, L536, L538, L541,L556, L577, M500, M510, M521 and M543 Floor-Ceiling construction.

JUNCTION BOX

  • Compact galvanized steel junction box with 24in3 internal volume.
  • One 1-1/8”, one 1/2”, three 7/8” knockouts and four Romex pryouts with strain relief.
  • Accepts 14-2, 14-3, 12-2, 12-3 U.S. and 14-2, 14-3, 12-2 Canadian NM cable.
  • Three 3-port push wire nuts with clear caps for quick and reliable mains voltage connections.

BAR HANGER

  • Swivel-headed bar hangers with pre-installed nail support housing at any point along span.
  • Captive nail penetrates standard and engineered lumber.
  • Adjusts from 13-5/8” to 25” wide.
  • Can be repositioned along short side or long side of plaster frame.

STC & IIC

  • Sound transmission class (STC) and Impact Insulation class (IIC) tested by a certified acoustical testing lab. STC and IIC comply redommendations for reducing noise including spoken word and others in multifamily and mixed-use structures.

LISTINGS

  • cULus Listed for Damp Location
  • cULus Listed for Wet Location (with specified trims)
  • cULus Listed for Feed Through
  • Certified under ASTM-E283 for Air tight construction

DIMENSION

INSTALLATION BY SWIVEL BAR HANGER

Additional information

color

black, Brown, RED

Installation

INSTALLATION BY SWIVEL BAR HANGER